Our range of sensors
Our sensor data sheets provide essential information about a sensor's specifications, helping users understand its capabilities
pH
- Parameter measurement
- pH, Temperature
- Range
- PH:0.0~14.0
Temperature: 0~50.0℃ - Accuracy
- pH: ±0.1pH
Temperature: ±0.5℃ - Resolution
- PH:0.01pH
Temperature:0.1℃
Dissolved Oxygen -DO
- Parameter measurement
- DO,Temperature
- Range
- Dissolved oxygen:0-20 mg/L,0-20 ppm;
Temperature:0-45℃ - Accuracy
- Dissolved oxygen: ±3%;
Temperature: ±0.5℃ - Resolution
- Dissolved oxygen: 0.1%/0.01mg/l
Temperature:0.1℃
Fresh Water Conductivity -EC & TDS
- Parameter measurement
- EC, TDS, Temperature
- Range
- EC: 0~2000μS/cm
TDS: 0~2000ppm
Temperature: 0~50.0℃ - Accuracy
- EC: ±1%FS
TDS: ±1%FS
Temperature: ±0.5℃ - Resolution
- EC: 1μS/cm
TDS: 1ppm
Temperature: 0.1℃
Salt Water Conductivity -EC & Salinity
- Parameter measurement
- EC, Salinity, Temperature
- Range
- EC: 0~100ms/cm
Salinity: 0~80.0ppt
Temperature: 0~50.0℃ - Accuracy
- EC: ±1%FS
Salinity: ±1%FS
Temperature: ±0.5℃ - Resolution
- EC: 0.01ms/cm
Salinity: 0.1ppt
Temperature: 0.1℃
Turbidity
- Parameter measurement
- Turbidity
- Range
- 0.01-100 NTU; 0.01-4000 NTU
- Accuracy
- Less than the measured value of ±1%, or ±0.1NTU, the largest of those values.
- Resolution
- 0.01NTU
Nitrite -NO2-
- Parameter measurement
- Ion,Temperature
- Range
- Ion:0.02~1000ppm(mg/L)
Temperature: 0~50.0℃ - Accuracy
- Ion: ±2% when 0~100mg/L at 25℃
Ion: ±5% when 0~1000mg/L at 25℃
Temperature: ±0.5℃ - Resolution
- Ion:0.01mg/L
Temperature:0.1℃
Nitrate -NO3-
- Parameter measurement
- Ion,Temperature
- Range
- Ion:0.02~1000ppm(mg/L)
Temperature: 0~50.0℃ - Accuracy
- Ion: ±2% when 0~100mg/L at 25℃
Ion: ±5% when 0~1000mg/L at 25℃
Temperature: ±0.5℃ - Resolution
- Ion:0.01mg/L
Temperature:0.1℃
Ammonia -NH3
- Parameter measurement
- Ion,Temperature
- Range
- Ion:0.02~1000ppm(mg/L)
Temperature: 0~50.0℃ - Accuracy
- Ion: ±2% when 0~100mg/L at 25℃
Ion: ±5% when 0~1000mg/L at 25℃
Temperature: ±0.5℃ - Resolution
- Ion:0.01mg/L
Temperature:0.1℃
Ammonium -NH4+
- Parameter measurement
- Ion,Temperature
- Range
- Ion:0.02~1000ppm(mg/L)
Temperature: 0~50.0℃ - Accuracy
- Ion: ±2% when 0~100mg/L at 25℃
Ion: ±5% when 0~1000mg/L at 25℃
Temperature: ±0.5℃ - Resolution
- Ion:0.01mg/L
Temperature:0.1℃
Potassium -K+
- Parameter measurement
- Ion,Temperature
- Range
- Ion:0.02~1000ppm(mg/L)
Temperature: 0~50.0℃ - Accuracy
- Ion: ±2% when 0~100mg/L at 25℃
Ion: ±5% when 0~1000mg/L at 25℃
Temperature: ±0.5℃ - Resolution
- Ion:0.01mg/L
Temperature:0.1℃
Doppler Flow
- Parameter measurement
- Flow,Temperature, Level
- Range
- Flow: 0.03~5.00m/s
Temperature: -10~60.0℃
Level: 0.05~10m (maximum range 10m) - Accuracy
- Flow: ±1.0% or ±1cm/s (highest value)
Temperature: ±1℃
Level: ±0.5% or ±0.5cm/s (highest value)
Depth (Pressure)
- Parameter measurement
- Pressure
- Range
- 0~200m
- Accuracy
- ±0.2%FS/±0.5%FS
- Resolution
- 0.01
Sonde
- Parameter measurement
- Up to six of the following: (Depth) Pressure, Temperature, pH, EC, Turbidity, DO, Chlorophyll, Blue-Green Algae, Salinity
Get in touch
WATR has been designed to improve water quality around the world by providing an easy, accurate and a reliable way of monitoring water conditions, if you have any enquiries or questions please get in touch. Send us your specific requirements and we will get back to you as soon as possible.